Product Description
Aquaprime is a two-component water-based epoxy primer with high electrostatic conductivity.
Storage Conditions/Shelf Life
12 months from the manufacturing date if stored properly in undamaged seal packaging at a temperature between 5°C and- 30°C. It should be kept in a cool, well-ventilated area.
Product Data
| Component | Aquaprime [R] Resin |
|---|---|
| Description | — |
| Appearance | Black Liquid |
| Component | Aquaprime [H] Hardener |
|---|---|
| Description | — |
| Appearance | Clear Liquid |
| Component | Description | Appearance |
|---|---|---|
| Aquaprime [R] Resin | — | Black Liquid |
| Aquaprime [H] Hardener | — | Clear Liquid |
Salient Features
- Easy to apply
- Gives a highly conductive surface
- Water-based system
- Solent free and odourless system
Uses
- Aerospace / Military areas
- Electronic industry
- Data processing
Mechanical /Physical properties
| Property | Test Method | Value and Unit |
|---|---|---|
| Mixing Ratio | NA | Pre-weighed kit |
| Finish | CPI* 1001 | Non-porous, matt |
| Pot Life | ||
| @ 10°C | CPI 1002 | 60 min |
| @ 20°C | CPI 1002 | ~45 min |
| @ 35°C | CPI 1002 | ~25 min |
| Surface Dry @ 35°C | CPI 1002 | ~20 min |
| Hard Dry (Open for foot traffic) @ 35°C | CPI 1002 | ~8 hours |
| Coverage | CPI 1010 | Pre-weighed kit to cover 50 sqm @ 100 micron |
| Tensile Strength | ASTM C 307 | > 90 Kg/cm² |
| Electrostatic Behaviour | – | < 10³ Ohm |
Method of Application
Substrate Quality
Application conditions

Substrate temperature: 10-40 °C

Substrate moisture content: - <5%

Relative humidity: 8o%max
Substrate Quality
Substrate Preparation
Mixing
Cleaning of Tools
Clean all tools and application equipment with water immediately after use. Hardened and/or cured material can only be removed mechanically
Packing: Aquaprime is available in pre weighed kit consisting of Resin, Hardener.
Storage Conditions
Handling & Safety
*Disclaimer: The Information provided is based on our experience, thorough investigations & sophisticated testing methodsbut due to the vast number of applications and usage methods, Chemsol Polymer Industries cannot accept responsibility of any kind for any particular result. It is the responsibility of the user to verify the suitability of the product for their end use, and in accordance with the rules and regulations of that country /territory. All information provided pertaining to our products should be treated only as guidance tool without any guarantee or warranty of any sorts.
* All CPI test methods are our scientifically designed internal test methods which can be shared upon request.